Ideal Rankine Cycle
Follow water through a pump, boiler, turbine, and condenser
Difficulty
Intermediate
Read time
6 min
Review status
Needs review
Concept sketch
Ideal Rankine Cycle
Illustrative model, not experimental data
Overview
The Rankine cycle models a steam power plant by separating heat transfer from work transfer in four steady-flow devices. Following the same state numbering through the loop makes the energy balance much easier to organize.
How to read it
- Track the same kilogram of fluid around the four devices.
- Distinguish work output from work input.
- Check that net work equals heat input minus heat rejection.
When to use it
- Organizing a basic steam-cycle calculation.
- Interpreting the effect of turbine and pump losses.
Number the states around the loop
State 1 is saturated liquid leaving the condenser. The pump raises it to boiler pressure at state 2. The boiler adds heat until state 3 at the turbine inlet. The turbine expands the steam to state 4, then the condenser returns it to state 1.
What ideal means here
Treat pump and turbine as adiabatic and internally reversible, so their ideal paths are isentropic. Neglect pipe pressure drops and changes in kinetic and potential energy. Boiler and condenser heat transfer occur at approximately constant pressure. Real devices require efficiency and loss corrections.
Use enthalpy differences per kilogram
With h in kJ/kg, the turbine work output is h₃ − h₄, pump work input is h₂ − h₁, and boiler heat input is h₃ − h₂. Subtract pump input from turbine output before calculating efficiency.
Property values come from the state
Use consistent steam tables or a water-property model for pressure, temperature, entropy, and phase. The ideal-gas equation is not a substitute in the saturated liquid–vapor region. Convert pressure units before estimating pump work from v Δp.
Worked example
For an illustrative four-state cycle, take h₁ = 200, h₂ = 205, h₃ = 3200, and h₄ = 2200 kJ/kg. These supplied values are for an energy-balance exercise, not a steam-table lookup.
1.Separate turbine output, pump input, and boiler heat.
2.Find net work and thermal efficiency.
3.Check conservation of energy.
The illustrative cycle converts 33.2% of supplied heat into net work.